DMP 120 (260-1255) Settings Faxback Doc. # 4417 SETTING PRINT FUNCTION SWITCHES There are four switches located at the right rear of the Printer. These switches allow you to customize some of the DMP-120 features for your own applications. When you receive the DMP-120, all switches should be set to OFF (i.e., in the down position). By setting certain switches ON, before turning the DMP-120's power ON, you can select different baud rates, interface modes, etc. POSITION │ SYMBOL │ OFF │ ON ─────────┼───────────┼────────────────────────┼─────────────────────────────── 1 │ NL/CR │ CR code generates │ CR code causes only │ │ CR + LF operation. │ Carriage Return operation ─────────┼───────────┼────────────────────────┼─────────────────────────────── 2 │NORMAL TEST│ Normal Operation is │ Self Test pattern is │ │ activated. │ generated automatically. ─────────┼───────────┼────────────────────────┼─────────────────────────────── 3 │ 1200 BPS │ When the Serial Inter- │ When the Serial Interface │ 600 BPS │ face is available, │ is available, transmission │ │ transmission rate is │ rate is set to 600 BPS. │ │ set to 1200 BPS. │ ─────────┼───────────┼────────────────────────┼─────────────────────────────── 4 │Parallel │ Parallel Interface is │ Serial Interface is │Interface │ available. │ available. ─────────┴───────────┴────────────────────────┴─────────────────────────────── CR TEST 600 BPS SERIAL │ │ │ │ │ │ │ │ │ │ │ │ ┌───┼──────┼──────┼──────┼───────┐ │ ┌┴─┐ ┌┴─┐ ┌┴─┐ ┌┴─┐ │ /\ │ │┌┐│ │┌┐│ │┌┐│ │┌┐│ │ │ ON SIDE │ ││││ ││││ ││││ ││││ │ │ │ │└┘│ │└┘│ │└┘│ │└┘│ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ │ OFF SIDE │ └┬─┘ └┬─┘ └┬─┘ └┬─┘ │ \/ └───┼──────┼──────┼──────┼───────┘ │ │ │ │ │ │ │ │ │ │ │ │ │ NORMAL │ PARALLEL │ │ NL 1200 BPS (abo-07/26/93)