Digital Multimeter (220-0181) Specifications Faxback Doc. # 8660 DC VOLTS Accuracy is shown as % of full scale, plus the number of digits between 5% of range and full scale (except on 1000 V scale). Ranges..............Resolution.....................Accuracy (Maximum Reading) 1000 V..............1 V.................+/-20 V, +/-2 Digits 399.9V............100 mV..................+/-1%, +/-2 Digits 39.99V.............10mV...................+/-1%, +/-2 Digits 3.999V..............1 mV..................+/-1%, +/-2 Digits 399.9 mV.........100 microV.............+/-1.5%, +/-2 Digits Input Impedance..............................10M Ohms in Parallel with 2 pF Response Time to Rated Accuracy.............................10 Seconds Max. Maximum Input......................................................1000 VDC AC VOLTS (True RMS Responding, AC Coupled) Accuracy is shown as % of full scale, plus the number of digits between 5% of range and full scale (except on 1000 V scale). Ranges...............Resolution............Accuracy (Maximum at 60Hz-1kHz Reading) 750 V...................1 V............30 V,+/-3 Digits 399.9 V.................100 mV..........3%, +/-3 Digits 39.99 V.................10 mV...........3%, +/-3 Digits 3.999 V.................1 mV............3%, +/-3 Digits 399.9 mV................100 microV......3%, +/-3 Digits Response Time to Rated Accuracy.............................10 Seconds Max. Allowable Crest Factor Range............................Ratio of 1:1 to 3:1 ..............................................................at Full Scale Input Impedance................................1 Mohm in Parallel with 2 pF Input Range......................................................+/- 60 dBm DC CURRENT Range..........Jack...........Reso-.................Accuracy (Max.Reading).................lution........................ 9.999A.........10A............10mA......+/-5.5%, +/-5 Digits 3.999A.........10A............1 mA......+/-5.5%, +/-5 Digits 399.9 mA...400/40 mA........100 microA....+/-2%, +/-2 Digits 39.99 mA...400/40 mA.........10 microA..+/-3.5%, +/-2 Digits 3.999 mA......4 mA............1 microA..+/-2.5%, +/-2 Digits AC CURRENT (True RMS Responding, DC Coupled at 1 kHz) Range...........Jack.............Reso-..............Accuracy (Max. Reading)...................lution..................... 9.99A...........10A..............10mA......5.5%, +/-3 Digits 3.999A..........10A...............1mA......7.5%, +/-3 Digits 399.9mA......400/40 mA...........100microA.3.5%, +/-3 Digits 39.99mA......400/40 mA............10microA.6.5%, +/-3 Digits 3.999mA.........4 mA...............1microA...4%, +/-3 Digits Maximum Allowable DC Level....................Less than Full Scale of Range Allowable Crest Factor Range......................1:1n to 3:1 at Full Scale RESISTANCE Ranges................Resolution....................Accuracy (Maximum Reading) 39.9 Mohms...........10 kohms...........+/-2.5%, +/-3 Digits 3.999 Mohms...........1 kohms.............+/-1%, +/-3 Digits 399.9 kohms..........100 ohms.............+/-1%, +/-3 Digits 39.99 kohms...........10 ohms.............+/-1%, +/-3 Digits 3.999 kohms............1 ohms.............+/-1%, +/-3 Digits 399.9 ohms............0.1 ohms..........+/-1.5%, +/-3 Digits Overload Protection.........................Fused-500 V AC/DC on All Ranges In-Circuit Voltage.................0.4 Volts or Less (<0.5V for 399.9 Ohms) Response Time.............................20 Seconds Max. on 40-Mohms Range .........................................4 Seconds Max. on All Other Ranges CAPACITANCE Ranges....................Resolution................Accuracy (Maximum Readings) 399.9 microF...............100 nF.........+/-6%, +/-3 Digits 39.99 microF................10 nF.........+/-3%, +/-3 Digits 3.999 microF................1 nF..........+/-2%, +/-3 Digits 399.9 nF....................100 pF........+/-2%, +/-3 Digits 39.99 nF.....................10 pF........+/-2%, +/-3 Digits 3.999 nF.....................1 pF.........+/-3%, +/-3 Digits General Specifications Operating Temperature.............................32° to 122°F (0° to 50°C) Maximum Common-Mode Voltage..............................500 VDC or Peak AC Dimensions......................................81/2 x 43/4 x 211/16 Inches Weight...................................................1 lb 7oz (Approx.) Power Requirements...........................................3 AA Batteries Battery Life (Alkaline)...................................300 Hours Minimum Battery Measurement Frequency.........................6 Per Minute, Typical Conversion/Bargraph Refresh Rate:.................Greater than 3 per second Digital Refresh Rate...............................Once every 8 conversions Standards...........................................................UL, FCC (RLR-11/29/93)