Telephone Tester (430-0114) Test Selection Buttons Faxback Doc. # 15703 Cord Press for Cord Test. Checks the number of wires in the Handset or Line Cord. Also verifies the condition of either cord. Loop Test Press to verify proper switch hook impedance parameters. Short Loop Sets electrical conditions which permits you to duplicate use with a close-by Central Office. Long Loop Presents conditions duplicating a connection to a Central Office of some distance from the test phone. Dial Press before initiating a test call to verify dialing accuracy. X-Mit Press to test handset transmitter operation. Recv Press to test handset earpiece operation. High Ring Checks ringer operation at high voltage level, simulating a SHORT loop. Low Ring Checks ringer operation at low voltage level to simulate a LONG loop. TEST SELECTION BUTTON INDICATORS When a Test Selection Button is pressed, the LED directly above will light. However, when either the DIAL, X-MIT or RECV Test Selection Button is pressed, not only will the LED above the button light, but either the SHORT LOOP or LONG LOOP LED will also light. (llg/all-06/21/95)