Thermistor (271-0110) Specifications Faxback Doc. # 7872 RELIABILITY High Temperature: The change ratio of nominal no load resistance should be within +/- 1.0%, compared with the initial value after the test sample is left in air of 110 degrees C for 1000 hours. Moisture: The change ratio of nominal no load resistance should be within +/- 1.0%, compared with the initial value after the test sample is left in air of 40 degrees C and 95% RH for 1000 hours. Temperature Cycle: The change ratio of nominal no load resistance should be within +/- 1.0%, compared with the initial value after the test sample is repeated 100 cycles by following cycle: One cycle means the test for 30 minutes in -30 degrees C, for 30 minutes in 90 degrees C. MECHANICAL TEST Terminal Strength: The shape and the characteristics should be no changed after added the weight of 0.1Kgf to the lead wire upon fixing the coated portion. Shock: The test samples should be no changed after two times of natural fall to a maple board from 1m high. SOLDERING Reasonable Soldering Condition Temperature: Max 260 degrees C Time: Within 20 sec (ALL-06/25/96)