35 MB Primary Hard Drive (260-4171) Settings Faxback Doc. # 5309 DRIVE SELECT / TERMINATION INFORMATION Quantum Q540 DRIVE SELECT Five jumpers are provided for logical drive number assignment. DS1, DS2, DS3, DS4 cause the drive to be selected when the active drive select line matches the installed jumper. Jumper G, when installed, causes the drive to be selected constantly. The Quantum part number for the jumper plug is 22- 10036. CONTROL CABLE TERMINATION If the Modem Q540 is the last drive at the end of the control signal cable, a 220/330 ohm terminator pack must be installed at PCB location RN 3. The terminator must be removed from RN 3 is the drive is not at the end of a string of drives. The Quantum part number for the terminator pack is 13-12302. │ │ │ TERMINATOR │ │ ┌──┐ │ │ │ │ │ │ │ │ │ │ │ │ DRIVE SELECT │ └────┐ │ │ ooooo │ │ └──┘ ooooo │ ┌────┘ │ │ P3 │ │┌───────┐ J1 J2 │ ││o o o o│┌────┐│││││││││││││││││││┌───────┐││││││││││┌─┘ │└───────┘│ │││││││││││││││││││││ ││││││││││││ └─────────┘ └┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┴┘ └┴┴┴┴┴┴┴┴┴┴┘ (css 07/30/93)