MPA-101 100-Watt  (320-2039)     Safety Indicators     Faxback Doc. # 14626
PA Amplifier

Your amplifier has two indicators that warn you of potential damage to the
amplifier.

The CLIPPING indicator lights when a sound source's signal exceeds its
mixing control setting.  If this happens, reduce the level of the
appropriate mixing control or reduce the MASTER VOLUME until the indicator
flickers only at peak volume levels.

The PROTECTION indicator lights if the amplifier gets too hot because of a 
power overload.  The amplifier's built in protection circuit temporarily 
interrupts the amplifier's power.  If this happens, press POWER to the out
position to turn off the amplifier, let the amplifier cool for about 15
minutes, and correct whatever caused the overload.  Then press in POWER to 
turn the power back on.

Note:  If the power does not immediately come on, turn off the power again,
       wait about 5 minutes, and press in POWER again.


(SP/all-04/20/95)