MPA-200 Stereo PA Amplifer (320-3003) Specifications Faxback Doc. # 14636 Input Impendance...................................................47k ohms Continuous Power Output (both channels driven) @ 20 Hz to 20 kHz........................100 watts per channel(8 ohm) RMS @ 1 Khz.................................120 watts per channel(4 ohm) RMS Total Harmoic Distortion.....................0.1% at rated power, at 8 ohms .05% at 100W power, at 4 ohms Frequency Response..................................10 Hz to 50 KHz +- 3 dB Input Sensitivity..........................0.5 volts for 100 watts at 8 ohm Signal to Noise Ration...................................90 dB (A-weighted) Speaker Impendance..........................................A,B (4,16 ohms) A + B (8-16 ohms) Power Requirement............................................6 Amp/250 Volt Power Fuse...................................................6 Amp/250 Volt Dimensions (HWD).............................5 5/6 X 18 7/8 X 14 1/4 inches (11.4 X 48 X 30.5 cm) Weight.....................................................26.45 lb (12 kg) The supply voltage is 120V AC / 60Hz. The power source must be insulated from other equipment Room Temperature: 77F (25C) Output Impedance: 8 Ohms Reference Power: 2 watts ITEMS UNIT NOMINAL LIMIT Continous Power Output 20 Hz W 100 85 (Both Channels Driven) 1 KHz W 100 85 at 8 Ohms, 0.5% THD 20 KHz W 100 85 Continous Power Output 20 Hz W 120 100 (Both Channels Driven) 1 KHz W 120 100 at 4 Ohms, 0.5% THD 20 KHz W 120 100 THD at 100W, 4 Ohms 1 KHz % 0.05 0.3 Frequency Response 10 Hz dB -1 +-3 1 KHz dB 0 0 0 dB=2W 50 KHz dB -1 +-3 S/N Ratio (A-WTD) 100 W dB 90 80 Input Sensitivity @ 100W Output 1 KHz V 0.5 0.3-0.7 Channel Separation 1 KHz dB 65 55 Clip LED On Level 1 KHz W 100 -1 dBV Note: Nominal specs represent the design specs. All units should be able to approximate these - some will exceed and some may drop slightly below these specs. Limit specs represent the absolute worse condition that still might be considered acceptable; in no case should a unit fail to meet limit specs. (SP/all-04/20/95)