Cassette Replacement (330-2001) Specifications Faxback Doc. # 15323 Mike This standard describes the requirements for a dynamic microphone type, handheld, for use in tape recorder. ELECTRICAL REQUIREMENTS Impedance:.........................................500 Ohms +/- 30% at 1KHz Directivity:...............................................Omni-Directional Sensitivity:..........................-78 +/- 3dB at 1KHz (odB=1V/microbar) Frequency Response:.............................................100Hz-10KHz MECHANICAL REQUIREMENTS Durability of Switch:..................Normal after 10,000 cycles operation Cord Strain Relief:......................Normal after supplied 5kg force at both end of mic or plug for 1 sec. Drop Test:.......................Normal after free fall from 1 meter height to concrete floor each one for 5 times Vibration Test:...................Normal after vibrations, 12Hz to 55Hz for 1 minute full amplitude 2mm for 1.5 hours at three axises Temperature Cycle Test:...............After exposure at -10 degrees C for 1 hour, at 25 degrees C for 1 hour, at 55 degrees C for 1 hour, 2 cycles, frequency response, sensitivity should be within specifications. Humidity Test:....................After exposure at 40 degrees C and 90-95% RH relative humidity for 48 hours, frequency response, sensitivity should be within specifications (The measurement should be done after 2 hours of conditioning at 25 degrees C) Operating Temperature:........................-10 degrees C to 55 degrees C (ALL-05/18/95)