70-Volt/100 Watt Line (320-1032) Specifications Faxback Doc. # 16226 Transformer Part Number: EX-5404 ELECTRIC CHARACTERISTICS Impedance:........................................................4-51 ohms Load Impedance:.....................................1 KHz 1V 4 Ohms +/- 10% Frequency Characteristics: Insertion Loss:.......................................1KHz 1V 1.0 dB Max Frequency Response:...............................50-10KHz +/- 1.0dB Max DC Resistance:.........................................Primary 0.2 Ohms Max Secondary 0.2 Ohms Max Turn Ratio:..........................................3.76 +/- 3% High Pot Test (Test voltage 1 minute) Primary Winding and Secondary Winding:.........................AC 1KV Primay Winding and Core:..........................................AC 1KV Secondary Winding and Core:.......................................AC 1KV Insulation Resistance:...............DC 500V 100M Ohms Min. between Primary winding and Secondary windings and between windings and core Heat Test:...............Transformer must be conditioned for 7 hours in 40C ambient temperature. After this test, transformer must be able to withstand high pot test and insulation resistance must be larger than 10M ohms. Lead (Pin, tensile test):....................Leads (Pins( must be withstand a pull of 2Kg for 10 seconds. Humidity Test:..................Transformer must be conditioned for 6 hours in 40C ambient temperature at 90 to 95% RH. After this test, transformer must be withstand pot test and insulation resistance must be larger than 5M ohms Inpregnation:.......................................................Varnish (ALL-07/28/95)