DX-351 (200-0215) Specifications Faxback Doc. # 8194 FM TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range Minimum 87.35 +or- 0.15 MHz Maximum 108.25 +or- 0.25 MHz Intermediate Frequency 10.7 +or- 0.1 MHz Maximum Sensitivity 90MHz 16 22 dBu 98MHz 16 22 dBu 106MHz 16 22 dBu Usable Sensitivity 90MHz 22 28 dBu 98MHz 22 28 dBu 106MHz 22 28 dBu Image Rejection 106MHz 26 20 dB IF Rejection 90MHz 70 50 dB 3dB Limiting (10mv) 98MHz 22 28 dB Minimum Output 98MHz 3 5 mv Tuning Indicator Sensitivity 98MHz 24 30 dBu AFC Hold Range 98MHz 500 300-700 kHz S/N Ratio 98MHz 46 36 dB Current Consumption 98MHz 80 100 mA AM Suppression 98MHz 36 30 dB Frequency Response (-6dB) 98MHz 150 250 Hz 98MHz 4200 3200 kHz Output Power 98MHz 180 150 mW 98MHz 150 120 mw THD 98MHz 2 4 % Overload Capacity 98MHz 100 % Calibration 90MHz +or- 1000 kHz 98MHz +or- 1000 kHz 106Mhz +or- 1000 kHz Lowest Battery Voltage 98MHz 1.9 2.1 V Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:......................................1kHz/22.5kHz Deviation MW (MEDIUM WAVE) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range Minimum 520 530 kHz Maximum 1740 1710 kHz Intermediate Frequency Minimum 455 +or- 3.5 kHz Maximum Sensitivity 600kHz 56 62 dBu 1000kHz 54 60 dBu 1400kHz 54 60 dBu Usable Sensitivity 600kHz 62 68 dBu 1000kHz 60 66 dBu 1400kHz 60 66 dBu Image Rejection 1400kHz 26 20 dB IF Rejection 600kHz 26 20 dB 3dB Limiting (10mv) 98MHz 22 28 dB Selctivity (+or- 10kHz) 1000kHz 18 12 dB Bandwidth (-6dB) 1000kHz 6 3.5-9 kHz THD 1000kHz 2 4 % Lowest Battery Voltage 1000kHz 1.9 2.1 V Tuning Indicator Sensitivity 1000kHz 60 66 dBu S/N Ratio 1000kHz 32 26 dB Current Consumption 1000kHz 100 120 mA Frequency Response (-6dB) 1000kHz 150 250 Hz 1000kHz 2.5 2.0 kHz Output Power 1000kHz 180 150 mW 1000kHz 150 120 mw Overload Capacity 1000kHz over 100 dBu A.G.C. F.O.M. 1000lHz 36 30 dB Calibration 600kHz +or- 25 +or- 50 kHz 1000kHz +or- 40 +or- 70 kHz 1400kHz +or- 40 +or- 70 kHz Whistle Modulation 21F/31F 10 15 % Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% LW (LONG WAVE) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range Minimum 145 150 kHz Maximum 285 281 kHz Intermediate Frequency Minimum 455 +or- 3.5 kHz Maximum Sensitivity 170kHz 64 dBu/m 220kHz 60 dBu/m 270kHz 60 dBu/m Usable Sensitivity 170kHz 66 72 dBu/m 220kHz 62 68 dBu/m 270kHz 62 68 dBu/m Image Rejection 106kHz 26 20 dB IF Rejection 270kHz 26 20 dB Selctivity (+or- 10kHz) 220kHz 18 12 dB Bandwidth (-6dB) 220kHz 6 3.5-9 kHz THD 220kHz 2 4 % Lowest Battery Voltage 220kHz 1.9 2.1 V Tuning Indicator Sensitivity 220kHz 64 70 dBu S/N Ratio 220kHz 32 26 dB Output Power 180 150 mW 150 120 mw Calibration 170kHz +or- 5 kHz 220kHz +or- 8 kHz 270kHz +or- 8 kHz Whistle Modulation 21F/31F 10 15 % Supply Voltage: DC:.................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW1 (Short Wave 1) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 4.53 4.60 kHz Maximum 5.15 5.05 kHz Maximum Sensitivity (S/N=6dB)4.8MHz 20 dBu Usable Sensitivity (S/N=20dB)4.8MHz 22 28 dBu Image Rejection (S/N=6dB) 4.8MHz 16 10 dB S/N Ratio (40dBu) 4.8MHz 32 26 dB Overload Cap (80% Mod @ 4.8MHz 80 60 dB 10% THD) Tuning Indicator Sensitivity 4.8MHz 22 28 dBu Output Power (40dBu in, 4.8MHz 180 150 mW Max out) Output Power (40dBu in, 4.8MHz 150 120 mW 10% out) Calibration 4.6MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW2 (Short Wave 2) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 5.87 5.95 kHz Maximum 6.37 6.25 kHz Maximum Sensitivity (S/N=6dB)6.15MHz 20 dBu Usable Sensitivity (S/N=20dB)6.15MHz 22 28 dBu Image Rejection (S/N=6dB) 6.15MHz 16 10 dB S/N Ratio (40dBu) 6.15MHz 32 26 dB Overload Cap (80% Mod @ 6.15MHz 80 60 dBu 10% THD) Tuning Indicator Sensitivity 6.15MHz 22 28 dBu Calibration 4.6MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW1 (Short Wave 3) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 7.00 7.05 kHz Maximum 7.74 7.65 kHz Maximum Sensitivity (S/N=6dB)7.35MHz 20 dBu Usable Sensitivity (S/N=20dB)7.35MHz 22 28 dBu Image Rejection (S/N=6dB) 7.35MHz 16 10 dB S/N Ratio (40dBu) 7.35MHz 32 26 dB Overload Cap (80% Mod @ 7.35MHz 80 60 dBu 10% THD) Tuning Indicator Sensitivity 7.35MHz 22 28 dBu Auto Scan 7.35MHz dBu Calibration 7.05MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW4 (Short Wave 4) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 9.41 9.50 kHz Maximum 10.02 9.90 kHz Maximum Sensitivity (S/N=6dB)9.6MHz 22 dBu Usable Sensitivity (S/N=20dB)9.6MHz 22 28 dBu Image Rejection (S/N=6dB) 9.6MHz 12 6 dB S/N Ratio (40dBu) 9.6MHz 32 26 dB Overload Cap (80% Mod @ 9.6MHz 80 60 dB 10% THD) A.G.C. F.O.M (80dBu input) dBu Tuning Indicator Sensitivity 9.6MHz 22 28 dBu Auto Scan dBu Calibration 9.45MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW5 (Short Wave 5) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 11.38 11.45 kHz Maximum 12.14 12.05 kHz Maximum Sensitivity (S/N=6dB)11.8MHz 22 dBu Usable Sensitivity (S/N=20dB)11.8MHz 22 28 dBu Image Rejection (S/N=6dB) 11.8MHz 12 6 dB S/N Ratio (40dBu) 11.8MHz 32 26 dB Overload Cap.(80% Mod @ 11.8MHz 80 60 dBu 10% THD) A.G.C. F.O.M (80dBu input) dB Tuning Indicator Sensitivity 11.8MHz 22 28 dBu Auto Scan dBu Calibration 11.8MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW6 (Short Wave 6) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 13.26 13.35 kHz Maximum 14.11 14.00 kHz Maximum Sensitivity (S/N=6dB)13.7MHz 22 dBu Usable Sensitivity (S/N=20dB)13.7MHz 22 28 dBu Image Rejection (S/N=6dB) 13.7MHz 12 6 dB S/N Ratio (40dBu) 13.7MHz 32 26 dB Overload Cap.(80% Mod @ 13.7MHz 80 60 dBu 10% THD) A.G.C. F.O.M (80dBu input) dB Tuning Indicator Sensitivity 13.7MHz 30 36 dBu Auto Scan dBu Calibration 13.35MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW7 (Short Wave 7) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 15.00 15.10 kHz Maximum 15.70 15.60 kHz Maximum Sensitivity (S/N=6dB)15.3MHz 24 dBu Usable Sensitivity (S/N=20dB)15.3MHz 24 30 dBu Image Rejection (S/N=6dB) 15.3MHz 10 4 dB S/N Ratio (40dBu) 15.3MHz 32 26 dB Overload Cap.(80% Mod @ 15.3MHz 80 60 dBu 10% THD) Tuning Indicator Sensitivity 15.3MHz 30 36 dBu Calibration 15.1MHz +or- 50 +or- 100 kHz Supply Voltage: DC...................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW8 (Short Wave 8) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 17.39 17.50 kHz Maximum 18.21 18.10 kHz Maximum Sensitivity (S/N=6dB)17.8MHz 24 dBu Usable Sensitivity (S/N=20dB)17.8MHz 24 30 dBu Image Rejection (S/N=6dB) 17.8MHz 10 4 dB S/N Ratio (40dBu) 17.8MHz 32 26 dB Overload Cap.(80% Mod @ 17.8MHz 80 60 dBu 10% THD) Tuning Indicator Sensitivity 17.8MHz 30 36 dBu Calibration 17.50MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% SW9 (Short Wave 9) TEST ITEM CONDITION NOMINAL LIMIT UNIT Tuning Range (S/N=6dB) Minimum 21.40 21.50 kHz Maximum 22.03 21.95 kHz Maximum Sensitivity (S/N=6dB)21.7MHz 24 dBu Usable Sensitivity (S/N=20dB)21.7MHz 24 30 dBu Image Rejection (S/N=6dB) 21.7MHz 10 4 dB S/N Ratio (40dBu) 21.7MHz 32 26 dB Overload Cap.(80% Mod @ 21.7MHz 80 60 dBu 10% THD) Tuning Indicator Sensitivity 21.7MHz 30 36 dBu Calibration 21.50MHz +or- 50 +or- 100 kHz Supply Voltage: DC:..................................................................3V R.O.:.............................................................50 mW Load:.............................................................4 Ohm Modulation:....................................................1kHz/30% (/all-02/01/95)