AFX-150 (430-1240) Specifications Faxback Doc. # 14120 Power Requirements:............................AC Adapter 120 VAC 50/60 Hz Connectors:............................................U.S.O.C. type RJ11C Decoding Circuitry: DTMF:.....................................................Standard DTMF PULSE:.............................................10 Pulses per Second CNG Tones:.................................................1100Hz +/-5% Ring Generator:.........................20 Hz 40 mA, will ring REN of 2 OPERATING PARAMETERS We supply this information to help you answer questions your phone company might ask. Interface:......................................................Loop Start Connector:.......................................................USOC RJ11 Ringer:..................................Standard Bridged Ringer, 16-68 Hz Sine or Square Wave, 40-130 Volts Ring Signal Loop Current Require:...............................20-80 mA DC (Off Hook) DC Resistance: Off Hook:..................................................150-600 Ohms On Hook:....................................................> 5 Megohms Loop Voltage Required:................................> 35 Volts (On Hook) (TK/all-03/13/95)