TAD-1000 (430-0740) Troubleshooting Faxback Doc. # 15254 We don't expect you to have problems with your TAD. But, if you do, refer to the following problem-solving information to find possible causes and remedies. If you try all of these remedies and still have problems, contact your local Radio Shack store for assistance. Problem Cause and Remedy The TAD records a Cause: The caller hung up without leaving a dial tone, a siren, message or without using the maximum beeping, or an time and your local telephone company operator's voice does not send out CPC signals. instead of a caller's message. Remedy: Press NEXT/YES to play the next message. The TAD does not Cause: The phone line is not properly connected. answer calls. Remedy: Check all phone line connections. Cause: The TAD is not plugged into the wall outlet. Remedy: Make sure the AC adapter is properly connected to the TAD. Cause: There is not enough free memory to record a message. Remedy: Erase messages. Cause: The TAD is not set to answer calls. Remedy: Press ANSWER. The outgoing Cause: You were too close to the microphone announcement is or you spoke too loudly when recording distorted your announcement. Remedy: Re-record the announcement, speaking in a moderate tone of voice about 18 inches from the microphone. Cause: There was too much background noise in the room when you recorded the announcement. Remedy: Re-record the announcement. The TAD does not Cause: You entered an incorrect remote respond to remote operation security code. commands. Remedy: Carefully re-enter your remote operation security code. If the TAD fails to respond, the security code might have reset to the default code. Enter the default remote operation security code (11). Cause: AC power failure. Remedy: Make sure that AC power is restored and the DC 9V adapter is properly connected to the TAD (see "Connecting the AC Adapter"). The TAD sounds Cause: The OGM is too short to allow remote three short beeps access when you access it by remote. Remedy: Record a new OGM at least 2 seconds long at the TAD. Cause: The TAD's memory is full. Remedy: Erase messages at the TAD. The battery light Remedy: Press NEXT/YES (after replacing the blinks all the time batteries. inspite of new batteries in this unit. (br/ir-04/09/96)