8-Zone Alarm System (490-0485) Hints and Tips Faxback Doc. # 14603 1. Q. How to reset the fire alarm zone? A. Press CANCEL to silence the alarm. Then open main panel of the alarm. Wait about 10 seconds for the system to reset. 2. A. You may use Grade-A service on the panel. 3. A. If armed and violated, the system will reset in five minutes even if it is still violated. The zone which was (or is) violated will have a flashing indicator. The panel will sound entry delay like normal, so you will want to notice the flashing zone LED at the keypad. CANCEL must be pressed in order to clear the display, but note that they display will not clear if the zone is still violated. The 490-0485 Alarm system WILL WORK without a battery. When it's keypad flashes its LED, it's data link is working. The Automatic Phone Dialer (Cat. No. 490-0433) will work with this alarm system. The dialer should be attached to either the Burglar Dialer Terminals (terminals 32/33) or the Fire Dialer Terminals (terminals 30/31). These dialer terminals are normally open circuits and should use the N. O. terminals on the dialer. Q: Can the Dicon Model 330S (490-0481), the 8-Zone Alarm System (490-0485), and the 4-Zone Alarm System (490-0475) smoke detectors be all set off together? A: The above-mentioned smoke detectors cannot all be set off together. However, a 3.6 kHz Piezo Buzzer (273-0060) can be connected to the fire siren output at each smoke detector location. (The ground from the smoke detector can be used for a five-wire install.) (SP/ir-08/08/95)