8-Zone Alarm System (490-0485) System Defaults Faxback Doc. # 14901 SYSTEM DEFAULTS Master Code: Used to arm or disarm system as well as access programmable Default- 1 2 3 4 system parameters. User Codes (6): Used to arm and disarm system only. Default- 0 0 0 0 Ambush Code: Used when an optional bus interface dialer. This code Default- 0 0 0 0 simulates a system disarm locally while actually dialing the monitoring service and transmitting a distress signal. If no dialer is present, this code will simply arm and disarm the system. Note: The default user codes (0 0 0 0) are null codes and will not disarm or arm the system. The user codes must be reprogrammed to become valid. The user will not be allowed to program the master code (0 0 0 0). User codes can be disabled by programming (0 0 0 0). Away Mode: Determines which zones are active in AWAY armed mode. Default - Zones 1 through 7 are assigned. Home Mode: Determines which zones are active in HOME armed mode. Default -Zones 1 through 5 are assigned. Delay Mode: Determines which zones are delayed in faulted while in AWAY Default -Zones mode. Default delay time for these zones is 30 seconds. 1,2,3,6 and 7 are assigned Day Mode: Determines which zones are active in DAY mode. Default-Zones 1 through 3 are assigned. (SP/all-04/25/95)