8-Zone Alarm System (490-0485) Test Mode Faxback Doc. # 14902 TEST The user may enter the test mode from the disarmed state at any time: 1) Press and release TEST/DELAY key. 2) TEST/DELAY LED on. a) System monitors all loops. b) Zone LEDs show current status. 1) If any loop changes state (clearfaulted or faultclear). a) When fault is fixed, pre-alarm and keypad sounds for 2 seconds. b) When fault is created, pre-alarm and keypad give a double sound (500ms on/off/on) c) Update zone's LED status indication. This allows the user to correct faults without returning to the front panel for verification until he is done. 2) if TEST or CANCEL key is pressed. a) TEST LED off. b) Return to disarmed state. 3) Press and hold TEST key for 2 seconds 4) While key is held Alarm repeatedly sounds BURGLAR alarm for 1 second, then FIRE alarm for 1 second. (Zone LEDs will continue to show the current status of each zone). 5) When TEST key is released. a) Stop alarm. b) Enter TEST mode, go to 2. (SP/all-04/25/95)