Safe House Remote (490-0484) Specifications Faxback Doc. # 15713 Keypad Nominal Limit 1. Exit Delay Control Time: 0 - 55 sec. +/- 1 sec. 2. Entry Delay Control Time: 0 - 55 sec. +/- 1 sec. 3. Automatic Alarm Reset: Burg. 300 sec. +/- 1 sec. 4. Trigger Resistance: 1) Normally open loops (Minimum loop resistance is 50 Kohm) a. When N. C. loop resistance is less 1.9 - 3.3 kohm than 100 ohm b. When N. C. loop resistance is less 1.7 - 2.8 kohm than 500 ohm 2) Normally closed loops (Maximum loop 2.4 - 4 kohm resistance is 500 ohm) 3) Fire Loop (End of line resistance 1.7 - 3.3 kohm is 2.2k ohm) 4) Fire Trouble 2 - 3.3 kohm 5) Response Time All Loops 7.5 ms 5 - 10 ms 6) Battery Check Voltage (lead acid battery) 11.5 volts 11 - 12 7) Secondary AC Current Consumption at 120 350 mARMS +/- 20% Volts (Armed, 1 keypad, no loads connected) 8) Standby Battery Current Consumption at 88 mArms +/- 20% 12 Volts (Armed, 1 keypad, no loads connected, ac off sleep mode) 9) A. C. Primary Power Requirements No load armed 1 keypad 20 Watts Acc. Loaded with 20 ohm resistor and 60 Watts Fire Alarm loaded with 6 ohm resistor 10) Serial Data Rate 1200 bps 11) Transformer External Output Voltage Load Power Supply Power Supply Alarm Accessory Keypads Accessory Output Alarm Output 87.5% 100% 112.5% 87.5% 100% 112.5% .3A .1A. 11.5 12.8 12.8 - - - .3A + .3A .1A 11.0 12.6 12.7 - - - .3A .2A 11.4 12.7 12.8 - - - .3A + .3A .2A 10.8 12.6 12.7 - - - .3A .3A 11.0 12.7 12.8 - - - .3A + .3A .3A 10.6 12.5 12.7 - - - .3A .4A 11.0 12.7 12.7 - - - .3A + .3A .4A 10.5 12.4 12.7 - - - 0 0 .1A 12.0 12.8 12.8 13.9 16.2 18.2 1A 0 .1A 11.6 12.8 12.8 12.0 14.0 15.9 2A 0 .1A 11.5 12.8 12.8 10.9 12.7 14.2 0 0 .2A 11.8 12.8 12.8 13.8 16.0 18.2 1A 0 .2A 11.3 12.8 12.8 11.9 13.7 15.7 2A 0 .2A 11.2 12.7 12.8 10.8 12.4 14.1 0 0 .3A 11.6 12.8 12.8 13.7 16.0 18.1 1A 0 .3A 11.0 12.8 12.8 12.2 13.8 15.7 2A 0 .3A 11.0 12.7 12.8 10.8 12.5 14.0 0 0 .4A 11.4 12.8 12.8 13.6 15.9 18.0 1A 0 .4A 10.8 12.7 12.8 11.7 13.7 15.5 2A 0 .4A 10.7 12.6 12.8 10.7 12.4 14.0 1A .3A .1A 10.8 12.7 12.8 10.7 13.6 15.5 2A .3A .1A 10.7 12.6 12.8 10.7 12.4 14.0 1A .3A .2A 10.4 12.6 12.7 11.6 13.6 15.5 2A .3A .2A 10.2 12.5 12.7 10.6 12.3 13.9 1A .3A .3A 10.3 12.4 12.7 11.6 13.5 15.3 2A .3A .3A 10.2 12.3 12.7 10.5 12.3 13.8 1A .3A .4A 10.6 12.3 12.7 11.7 13.5 15.3 2A .3A .4A 10.5 12.0 12.7 10.6 12.2 13.7 1A .3A + .3A .1A 10.4 12.2 12.7 11.6 13.5 15.2 2A .3A + .3A .1A 10.3 12.0 12.7 10.6 12.3 13.8 1A .3A + .3A .2A 10.3 12.0 12.7 11.5 13.3 15.1 2A .3A + .3A .2A 10.1 11.8 10.7 10.6 12.1 13.7 1A .3A + .3A .3A 10.1 11.8 12.7 11.5 13.3 15.0 2A .3A + .3A .3A 9.9 11.6 12.6 10.5 12.0 13.5 1A .3A + .3A .4A 10.0 11.7 12.6 11.5 13.2 14.9 2A .3A + .3A .4A 9.8 11.4 12.6 10.4 12.0 13.5 Note: Voltages +/- 6%. all loads resistive. 12) Battery Charge Voltage Nominal Limit Constant Voltage: 14.0 volts 13.8 - 14.1 volts 13) Input Terminals Zone 1 a. Normally open 5 and 3 b. Normally closed 4 and 3 Zone 2 a. Normally open 6 and 8 b. Normally closed 7 and 8 Zone 3 a. Normally open 10 and 8 b. Normally closed 9 and 8 Zone 4 a. Normally open 11 and 13 b. Normally closed 12 and 13 Zone 5 a. Normally open 15 and 13 b. Normally closed 14 and 13 Zone 6 a. Normally open 16 and 18 b. Normally closed 17 and 18 Zone 7 a. Normally open 20 and 18 b. Normally closed 20 and 18 Panic Zone a. Normally open 1 and 3 b. Normally closed 2 and 3 Fire Zone a. Terminated w EOLM 37 and 38 Keypad Data2 41 and 42 A.C. Power 21 and 22 Battery 23 and 24 14) Output Terminals Pre-Alarm 34 and 35 Accessory Power 25 and 26 Fire Detector Power 36 and 38 Keypad Power 39 and 38 Keypad Power 39 and 42 Keypad Data 40 and 42 External Alarm (Burg.) 29 and 28 2 amps. maximum External Alarm (Fire) 27 and 28 2 amps. maximum Alarm Relay Contact 12 VDC 2 amps max Burglar (N.0). 33 and 32 Fire (N.O.) 30 and 31 15) Fuses a. Burglar 250V, 2A b. Fire 250V, 2A c. Accesory/Smoke Detector 250V, 1.25A d. Battery 250V, 4A (pm/all-06/21/95)