Home Alarm Center (490-0451) System Wiring Faxback Doc. # 17575 Alarm Panel Terminal Description 1 Instant Loop NO 2 Instant Loop NC 3 Loop Common (Gnd) 4 Delay Loop NC 5 Delay Loop NO 6 Panic Momentary NO 7 Remote Keypad Gnd 8 Remote Keypad Data 2 9 Remote Keypad +12VDC 10 Remote keypad Data 1 11 Burglar Alarm Relay NO (to 24VDC @ 1A max) 12 Burglar Alarm Relay NO 13 PreAlarm Gnd 14 PreAlarm & Accessory +12VDC (750mA max total current draw) 15 Siren Gnd 16 Siren +12VDC (1A max) 17 AC Input 12VAC 60Hz 18 AC Input 30VA Min. NOTE: Up to four (4) keypads may be added to this panel. The 49-452 and 49-484 are the only acceptable keypads for this panel, as this keypad uses a PROPRIETARY data protocol to communicate to the panel. Keypad Addressing: Keypad Addressing: Keypad #1: SW1 Off,SW2 Off Keypad #2: SW1 On, SW2 Off Keypad #3: SW1 Off,SW2 On Keypad #4: SW1 On, SW2 On Keypad Note: The alarm center recognizes all connected keypads when it is first powered up, and then responds ONLY to those keypads. All keypads must have a unique address. Changing Pass Code: With panel DISARMED, and no zones violated press and hold the "*" on the keypad until the LOOP indicator slowly flashes. Within 30 seconds, enter the old password (default is 1234), the LOOP indicator will go out, then enter the new pass code. The LOOP indicator will go on again. (/all-10/20/95)