Dual Floodlight Infrared Security System (610-2604) Adjusting Security System Faxback Doc. # 19255 This procedure adjusts the aim of your security system's sensor head and floodlights for best coverage. For now, simply set the controls as instructed. For a detailed description of each control's function refer to "Operation Settings," Faxback Doc. # 19256. Before you turn on the power: 1. Open the control panel cover by turning the metal locking screw. 2. Set the DUSK control fully clockwise to LIGHT. 3. Set the RANGE control fully clockwise to MAX. 4. Use a flat bladed screwdriver to set TIME DELAY control to 0.1. 5. Swivel the sensor head to point toward the area you want to cover. Be sure the sensor head remains level from side to side and level with the ground. CAUTION: Aim the sensor head below the horizon. Direct sunlight can damage the sensor. However, don't point the sensor head downwards. This reduces its range. For optimum operation, position the sensor head level with (parallel to) the ground. 6. Aim the floodlights at the area you wish to light. If necessary, loosen the screws to swivel the lamp holders. 7. Turn on the power and wait for 1 minute. 8. Walk around the covered area. Whenever you move, the floodlights come on and remain on until 6 seconds after you stop moving. If necessary, reorient the sensor head so that normal road traffic does not activate your security system. Tighten the locking nut on the sensor head and proceed to the next section to set all controls for proper operation. (CS 12/26/95)