Plug'N Power Split Receptacle Module (610-2685) Installation Faxback Doc. # 19299 1. Turn off power at circuit breaker or fuse. 2. Using a screwdriver, turn HOUSE CODE selector on Wall Outlet Module to same letter on Control Center HOUSE CODE selector. 3. Turn UNIT CODE dial to an unused number from 1 to 16. If you pick the same number as on another module, they will go ON and OFF together. 4. Remove existing wall plate and old outlet from box, and disconnect wires. 5. Connect wires on Wall Outlet Module (white and black) to same two wires that went to old wire nuts. Connect the green wire on Wall Outlet Module to the green or bare ground wire or to the wall box. 6. Attach module to wall box. 7. Make a note of the UNIT CODE number for each wall outlet. (CS 1/18/96)