Telephone Responder (610-2692) Troubleshooting Faxback Doc. # 19412 If a particular Module won't go on or off from the buttons on the Telephone Responder: Check that you have power to the outlet controlling the Module and the switch on the light or appliance is ON. Check that the Unit Code on the Module is set to the correct number. Check that the Housecode on the Module and the Telephone Responder are set to the same letter. Try plugging the Module and the Responder into the same outlet. If the Module doesn't work in ANY outlet, not even with the Module and the Responder in the same duplex receptacle (top and bottom) replace the Module. If the Module works in some outlets but not in others, call 1-800-843-7422 or contact your local Radio Shack store for help. If you can't control ANY Modules from the Telephone Responder: Check that you have power to the outlet for the Telephone Responder. Check that the Housecode on the Telephone Responder is set correctly. Try plugging the Module and the Telephone Responder into the same outlet. If NONE of your Modules work in ANY outlet, not even with the Module and the Telephone Responder in the same duplex receptacle (top and bottom) replace the "Telephone Responder." If the Telephone Responder works in some outlets but not in others, call 1-800-843-7422 or your local Radio Shack store for help. INTERCOM SYSTEMS Intercom systems which send voice signals over existing electrical wiring may interfere with the operation of the Telephone Responder when the intercom is in use. If the Intercom system has its own separate wiring it will not cause a problem. POWER INTERRUPTIONS When the power is restored after an outage, Lamp Modules and Wall Switch Modules will normally be OFF. Appliance Modules will stay as they were before the interruption. (CS 1/15/96)