Home Alarm Center (490-0451) Addendum Faxback Doc. # 32101 Some information contained in the 'System Wiring Connections' Chart on Faxback Doc. # 33422 needs clarification. Although both this chart and the chart on the back of your alarm system's front panel show that a device connected to Terminal 14 must be rated no higher than 50 mA, this is not true if you are connecting one side of a remote security device to this terminal. As instructed in 'Connecting and Powering a Remote Security Device' on Faxback Doc. # 33422, you can safely connect a remote security device that uses 12 Volts and is rated at 750 mA or less to Terminals 14 and 15 of your alarm system. The instructions describing where to install your system's jumpers (in 'Jumpers on Normally-closed Terminals' starting on Faxback Doc. # 33422 of your Owner's Manual are incorrect. If you installed a normally-closed loop of sensors only in the instant zone, install a jumper only between Terminals 3 and 4. If you installed a normally-closed loop of sensors only in the delayed zone, install a jumper only between Terminals 2 and 3. (IR-04/19/96)