12.6VCT @ 3A Transformer (273-1511A) Specifications Faxback Doc. # 16365 ELECTRICAL DATA Rating Primary:.......................................................120V/60Hz Secondary:.....................................12.5VAC @ 3 Amp 14.05 VAC Tolerance:...........................................................+/- 5% Primary Current No Load (Io):.................................................140 mA MAX Loading (IL):..................................................600mA MAX DC Resistance Primary:.............................................14.702 Ohms +/- 10% Secondary:............................................0.286 Ohms +/- 10% Core Loss:....................................................4.0 Watts Max Temperature Rising:........................75C MAX at Primary Coil measured with hot resistance method Insulation Resistance:..............................500 VDC 100 M Ohms min. Hi-pot Test:......................1080 VAC for 1 minute between primary and secondary and core without breakdown. MATERIAL Bobbin:............................................................Nylon 66 Lead Wire AWG #:.............................................................22/18 Insulation:.................................................UL-1015 VW-1 Core:.............................................Hilite silicon steel core Size:..........................................................EI-60/0.5 Impregnation:.......................................................Varnish (ALL-08/07/95)