24VAC CT UL Transformer (273-1366A) Specifications Faxback Doc. # 9881 ELECTRICAL DATA Rating: Winding: Primary:................................................120VAC 60 Hz Secondary: Loading:.......................................25.2VAC CT @ 0.45A No Load:...............................................28.5VAC CT Tolerance:..........................................................+/- 5% Primary Current: No Load (Io):.....................55 mA TRMS MAX at input 120 VAC 60 Hz Loading (IL):...........................................150 mA TRMS MAX DC Resistance: Primary:.......................65 Ohms +/- 15% measured at 25 degrees C Secondary:.............................................3.0 Ohms +/- 10% Core Loss:..............................2 Watts MAX. AT INPUT 120VAC 60 Hz Temperature Rising:...............50 degrees C MAX AT 25 degrees C ambient Insulation Resistance:..............:...................500 VDC 100 M min. Hi-pot Test:.....................1240 VAC for 1 minute between primary and secondary, primary and core 600 VAC For 1 minute between secondary and core MATERIAL Bobbin:..............................................................Nylon Lead Wire:.........................................................AWG #22 Insulation:............................................UL1015 1007 FR-1 Core:......................................................Size: EI-48/.5 Hilite silicon steel core Impregnation:......................................................Varnish (ALL-01/25/95)